Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels

Model NO.: KPLB-100
Loading Method: Dynamic Load
Display: Digital
Control: Computer & Manual Control
Weight: 350-13200kg
Power Source: 110-480V
Oil Cylinder Position: Nothing
Name: Portable Generator Loadbank 100kw for Load Testing
Power: Electronic
Power Factor: PF = 1.0 or 0.8
Usage: Auto Testing Machine
Frequency: 50Hz/60Hz
Color: Green/White/Blue/Red/Yellow
Load Step: 10kw
Rated Power: 0-100kw
Duty Cycle: Continuous
Power Range: 100kw to 2500kw
Trademark: KEYPOWER
Transport Package: Standard Exportation Package
Specification: 1900x1600x1900 mm
Origin: China
HS Code: 8514109000
Model NO.: KPLB-100
Loading Method: Dynamic Load
Display: Digital
Control: Computer & Manual Control
Weight: 350-13200kg
Power Source: 110-480V
Oil Cylinder Position: Nothing
Name: Portable Generator Loadbank 100kw for Load Testing
Power: Electronic
Power Factor: PF = 1.0 or 0.8
Usage: Auto Testing Machine
Frequency: 50Hz/60Hz
Color: Green/White/Blue/Red/Yellow
Load Step: 10kw
Rated Power: 0-100kw
Duty Cycle: Continuous
Power Range: 100kw to 2500kw
Trademark: KEYPOWER
Transport Package: Standard Exportation Package
Specification: 1900x1600x1900 mm
Origin: China
HS Code: 8514109000

Keypower 100kw/125kva Inductive Power Factor Adjustable Load Banks with Wheels

Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels

Product Details >>

KEYPOWER GENERATOR TESTER SPECIFICATIONS
Measurement Range Accuracy Resolution Overload
Voltage (V) 10.0~500.0V ± (0.4% reading+0.1%range) 0.1V 600V
Current (A) 0.030~5.000A  ± (0.4% reading+0.1%range) 0.001A 6A
Power According to volt range 
&  current range
Power factor =1.0 <200W 0.1W  
± (0.4% reading+0.1% range) ≥200W 1W
Power factor =0.5 ≥2kW 10W
± (0.8% reading+0.2% range)  
Power Factor 0.20~1.00 ±0.02 0.001  
Frequency 45~65Hz ±0.2Hz 0.01Hz  
Running Time 99h59m ±2min/hour 1 minute  
Energy
 (kWh)
99999kWh  Power factor= 1.0 0.001kwh  
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic Analysis 
(%)
2-50 times 
and total harmonic
     
 
Models You Can Choose
Model Testing 
capacity
Type 
of
 load
Duty Cooling 
system
Phase Rated 
Testing 
Voltage
Rated
 Frequency
Dimensions   
   (L*W*H)
 (mm)
Weight
 (kg)
KPLB-100 0 - 100 kw Resistive 
or 
Reactive, 
 PF = 
1.0 or 0.8
Continuous Industrial 
grade 
axial fan
Available
 at both 
single 
and 
three 
phase
110-480 
VAC
50/60 Hz 960*960*1400 320
KPLB-200 0 - 200 kw 1300*1200*1570 500
KPLB-300 0 - 300 kw 1600*1200*1700 900
KPLB-400 0 - 400 kw 1600*1400*1700 1000
KPLB-500 0 - 500 kw 2100*1560*1700 1200
KPLB-600 0 - 600 kw 2100*1560*1700 1300
KPLB-700 0 - 700 kw 2100*1560*1800 1400
KPLB-800 0 - 800 kw 2100*1660*1900 1600
KPLB-1000 0 - 1000 kw 2200*1900*2150 2000
KPLB-2000 0 - 2000 kw 20 ft container 6000
KPLB-5000 0 - 5000 kw 40HC container 16000

Specifications

100-2000KW Load Bank for Generator Load Test:

1.Premium components
2.Durable and reliable
3.Easy to transport 
Load bank is a simulating load test equipment used for generators, UPS,
battery banks etc power systems load test.
 

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
    
Siemens switches, knobs and indicators. 
  
OMRON intermediate relays. 
PHOENIX terminal blocks. 
6.  Parameter measuring accuracy grade: 0.3 
7. Load control accuracy: ± 5%. 
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m). 
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). " 
11. Operating environment:
Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ºC
Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.

Any question, please contact me directly. 
Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels
Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels
Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels
Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels





 

 

 

 

 





 

 

 

 

 

 

 

 

 

 

 

Keypower 100kw/125kva Inductive Power Factor Adjustable Load Banks with Wheels

Keypower 100kw/125kVA Inductive Power Factor Adjustable Loadbanks with Wheels

Product Details >>

KEYPOWER GENERATOR TESTER SPECIFICATIONS
Measurement Range Accuracy Resolution Overload
Voltage (V) 10.0~500.0V ± (0.4% reading+0.1%range) 0.1V 600V
Current (A) 0.030~5.000A  ± (0.4% reading+0.1%range) 0.001A 6A
Power According to volt range 
&  current range
Power factor =1.0 <200W 0.1W  
± (0.4% reading+0.1% range) ≥200W 1W
Power factor =0.5 ≥2kW 10W
± (0.8% reading+0.2% range)  
Power Factor 0.20~1.00 ±0.02 0.001  
Frequency 45~65Hz ±0.2Hz 0.01Hz  
Running Time 99h59m ±2min/hour 1 minute  
Energy
 (kWh)
99999kWh  Power factor= 1.0 0.001kwh  
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic Analysis 
(%)
2-50 times 
and total harmonic
     
 
Models You Can Choose
Model Testing 
capacity
Type 
of
 load
Duty Cooling 
system
Phase Rated 
Testing 
Voltage
Rated
 Frequency
Dimensions   
   (L*W*H)
 (mm)
Weight
 (kg)
KPLB-100 0 - 100 kw Resistive 
or 
Reactive, 
 PF = 
1.0 or 0.8
Continuous Industrial 
grade 
axial fan
Available
 at both 
single 
and 
three 
phase
110-480 
VAC
50/60 Hz 960*960*1400 320
KPLB-200 0 - 200 kw 1300*1200*1570 Biohazard Waste Treatment manufacturer, choose the high quality Biohazard Waste Management,Medical Biohazard Waste Disposal, etc.

Biological laboratory waste disposal equipment

Biomedical Waste Disposal,Biomedical Waste Management,Medical Biohazard Waste Disposal,Medical Hazardous Waste Disposal

Henan Liying Environmental Science and Technology Co., Ltd. , https://www.disposingmedicalwaste.com