Discussion on Ammonia H2S Alarm System Solution for Industrial Sewage and Wastewater Treatment Plants

Before discussing the installation method of ammonia hydrogen sulfide gas alarms in industrial wastewater and wastewater treatment plants, Andre Liaogong explained that the concentrations of ammonia, carbon monoxide, and hydrogen sulfide that should be detected during the production process in industrial wastewater and wastewater treatment plants are excessive. , Methane, hydrogen chloride, chlorine dioxide and other toxic and harmful gases, but also need to test the oxygen content of oxygen in the operation site of industrial sewage and wastewater treatment plants. The following Ander measurement instrument manufacturers take ammonia as an example;

Let us share in detail the use and precautions of the alarm device for ammonia leakage concentration in industrial wastewater and wastewater treatment plants;
Industrial wastewater and wastewater treatment plants produce large amounts of ammonia during production. Since ammonia is a colorless gas and has a strong irritating gas, it burns the mucous membranes of the skin, eyes, and respiratory organs. Excessive inhalation can cause lung swelling. Until death. Therefore, protection against ammonia gas in sludge treatment plants is necessary and must be well prevented.
Many people do not understand the role of industrial wastewater treatment plants and operating principles, but do not know that industrial wastewater wastewater in the process of wastewater treatment wastewater will produce a lot of ammonia. To this end, Andre Technology has brought about a process of reducing, stabilizing, and harmlessly concentrating, conditioning, dehydrating, stabilizing, drying, or incinerating wastewater effluents from industrial wastewater and wastewater treatment plants. What should be done to produce ammonia gas in the harmless processing of this industrial wastewater and wastewater treatment plant?
In order to solve the problem that the sludge treatment plant may produce ammonia gas during the treatment of industrial wastewater and wastewater, common measures and measures, such as wearing gas masks and anti-corrosion wearable equipment, have not been able to completely perform safety precautions. In response to this problem, Ander developed and designed an ammonia gas leakage alarm device specifically designed for ammonia treatment in industrial wastewater and wastewater treatment plants. It can quickly, accurately, and stably detect ammonia concentrations and take intelligent protection measures. Kill the harm completely in the bud.
How to use ammonia alarm equipment for industrial wastewater and wastewater treatment plants?
It is usually necessary to determine the number and installation location of ammonia gas detectors used in industrial wastewater and wastewater treatment plants, followed by fixed installation and commissioning tests, and later normal maintenance operations.
A, industrial sewage wastewater treatment plants using ammonia alarm probe number
Since the single probe of the ammonia alarm can detect the orientation of 20-30 square meters, it is very good for the relatively closed environment, such as the production workshop, to judge the number of ammonia alarm probes, and only needs to treat the detection environment. Divide the square volume by 20-30 square meters.
For open air environments such as outdoor use, the number of ammonia gas detectors used in a sludge treatment plant needs to be considered from a safety point of view. At this time, the point where ammonia gas is easily leaked (pipeline interface, etc.) and safety detection are specified. The ammonia leak alarm device must be installed. In this case, the number of ammonia gas detectors need to be customized for the specific environment.
Second , the industrial sewage and wastewater treatment plant ammonia alarm installation location
The ammonia alarm device is divided into two parts: the probe and the alarm controller host. The probe is installed at the operation site, and the gas alarm control host is installed and monitored to facilitate the monitoring environment. Here, the installation position of the ammonia gas alarm in the sludge treatment plant is mainly introduced for the installation position of the ammonia gas alarm probe. Select an ammonia gas leak location to install the ammonia gas alarm device, and install an ammonia gas alarm probe at the location where the operator's work environment does not affect the normal operation.
III . Commissioning and testing of ammonia alarm for industrial sewage and wastewater treatment plants
After installing the ammonia alarm equipment in the industrial wastewater and wastewater treatment plant, the equipment needs to be tested and debugged. In order to ensure that the supporting equipment can detect the safety leakage with high efficiency and take timely measures, the industrial wastewater can be realized in a real sense. Wastewater treatment plant ammonia protection work. Debugging the ammonia alarm device is very simple, just plug in the power cable and see if each probe and host display is normal. It is also very easy to test the ammonia alarm device. Take a certain amount of ammonia gas and place it in the probe part of the ammonia gas alarm. When the ammonia gas concentration appears and reaches the lower explosion limit, an alarm warning will be issued and the equipment will be installed. Start linkage settings such as solenoid valves and exhaust fans.

Goodsense 3.0Ton Electric Side Loader Forklift advantages:

- Work in Narrow Aisle 
- Side loading advantage
- Used of long objects

- Rubber Mounted Half Open Cabin

- Multi-Direction Operation

- 3 Wheel hydrostatic Drive

- Load Sensing Steering

- 4 Way Lever Positioning of Wheels

 

General

 

 

 

Model

 

FBS30

Power Type

 

Electric

Load Capacity

kg

3000

Load centre

mm

500

Tyre

 

 

 

Tyre

 

 

Pneumatic Tyre

Front Tyre

 

28×9-15-12PR

Rear Tyre

 

28×9-15-12PR

Overall Dimension

 

 

 

Lift Height

mm

3600

Fork Size

L×W×T

mm

1070×125×45

Mast Tilt Angle

F/R

.

4/6

Mast Lowered Height

mm

2420

Mast Extended Height(with backrest)

mm

4255

Length to face of fork(Without fork)

mm

4400

Overall Width

mm

2000

Cabin Height

mm

2520

Loading Plane Height

mm

930

 


 3.0Ton Electric Side Loader Forklift

 

Application Area:

1.Warehouse

2.Port

3.Factory

4.Distribution Center

5.Logistics

 

If you have any other questions,please contact us directly.Our forklift are all with high quality,and you can choose any other engine to equip.It can be produced according to your idea.And we invite you to visit our factory.

3.0Ton Electric Side Loader Forklift

3.0Ton Electric Side Loader Forklift,Electric Side Loader Forklift,Special Electric Side Loader

ZHEJIANG GOODSENSE FORKLIFT CO.,LTD , https://www.goodsenseforklift.com